Inference Capacity Where the Users Are — Prefabricated, Shipped and Commissioned as a Unit.
Factory-built modules with GPU or LPU inference nodes, integrated power and liquid cooling, delivered to metro edge sites, parking structures, campuses and industrial yards. Engineered once, repeated as many times as demand requires.
Who This Is For
- Model and application companies that need low-latency inference in specific metros
- Telecom and real-estate operators monetising sites with power and fiber
- Enterprises placing inference next to data that cannot move — plants, hospitals, campuses
- Teams that need capacity in weeks and cannot wait for a hall fit-out
What's Included
Module Selection and Engineering
Vertiv MegaMod and Schneider-class prefabricated enclosures sized to the node count, with integrated cooling and power.
Inference Node Configuration
GPU nodes (L40S, B200/B300, HGX) or LPU and ASIC inference platforms chosen for the model mix and latency targets.
Site Preparation
Pad, utility connection, fiber entry, security fencing and permitting at each location.
Integration and Shipping
Racks, fabric, storage and cooling installed and tested at the factory; module shipped as a sealed unit.
Commissioning
On-site power and cooling commissioning, network turn-up, burn-in and handover to your platform team.
Fleet Operations
Remote monitoring and smart hands for distributed sites under our managed NOC, if required.
Reference Specifications
Starting points. Every engagement is engineered to the workload, site and budget in front of us.
| Module capacity | 250 kW to 1 MW IT load per module; multiple modules per site |
|---|---|
| Compute | NVIDIA L40S / B200 / B300 nodes, HGX systems, or LPU/ASIC inference platforms |
| Cooling | Integrated in-row or liquid cooling with external dry coolers; rear-door HX for air-adjacent nodes |
| Power | Utility feed with integrated UPS and optional generator; 415 V distribution to racks |
| Connectivity | Dual fiber entry, 100/400G uplinks, private interconnect to cloud regions where needed |
| Security | Access control, CCTV and intrusion detection integrated to the NOC |
How We Deliver
- 1
Site and Demand Model
Weeks 1–2Where the users and data are, latency targets, node count per site, power and fiber availability.
- 2
Engineering and Order
Weeks 2–4Module configuration, site civil design, permitting, equipment orders.
- 3
Factory Build
Weeks 4–10Enclosure fit-out, rack integration, testing at the factory while the pad is prepared.
- 4
Ship and Commission
Weeks 10–12Delivery, placement, utility and fiber tie-in, commissioning and handover.
Questions We Get Asked
How is this different from a shipping-container datacenter?
Purpose-built prefabricated modules carry proper fire suppression, cooling, power and serviceability designed for GPU density. Repurposed containers rarely meet those requirements or local code.
Can modules be moved later?
Yes. The module is a sealed unit; with a prepared pad and connections at the new site it can be relocated and recommissioned.
Who operates a fleet of distributed sites?
Your platform team, or our NOC. We design every module with remote monitoring and out-of-band access so distributed operations do not require staff on site.
Request a Quotation
Pre-tagged as Edge inference modules. A solutions engineer responds the same business day.
Next: Build-vs-Rent Advisory